IEC 61968 PDF

IEC specifies the information content of a set of message types that can be used to support many of the business functions. INTERNATIONAL. STANDARD. IEC. First edition. Application integration at electric utilities –. System interfaces for distribution management. To build a scientific and efficient Distribution Management System (DMS), it is necessary to achieve sharing of data and avoid information silos.

Author: Akikree Zulkijind
Country: Bangladesh
Language: English (Spanish)
Genre: Sex
Published (Last): 21 August 2008
Pages: 265
PDF File Size: 5.49 Mb
ePub File Size: 5.39 Mb
ISBN: 192-1-78526-595-4
Downloads: 97457
Price: Free* [*Free Regsitration Required]
Uploader: Durn

Proceed to Checkout Continue Shopping. By providing a standard way of representing power system resources as object classes and attributes, along with their relationships, the CIM facilitates the integration of network applications developed independently by different vendors, between entire systems running network applications developed independently, or between a system running network applications and other systems concerned with different aspects of power system operations, such as generation or distribution management.

This document is intended for two distinct audiences, data producers and data recipients, and may be read from those two perspectives. Provides a set of guidelines and general infrastructure capabilities required for the application of the EMS-API interface standards. This new edition includes the following significant technical change with respect to the 61698 edition: This set of standards is limited to the definition of interfaces.

Solved power system state profiles IEC IEC specifies the information content of a set of message payloads that can be ifc to support many of the business functions related to network operations.

Supplies terms and abbreviations that are either specific to the series, or that require explanation because of the way that they are used. This glossary, accompanying the IEC series, is the second part in the series that, taken as a whole, defines interfaces for the major elements of an interface architecture for distribution management systems DMS.

  MAKING A REFRACTOR TELESCOPE NORMAN REMER PDF

IEC 61968-61970

As the voice of the U. Typical uses of the message types include network extension planning, copying feeder or other network data between systems, network or diagram edits and asset inspection. Subscription pricing is determined by: This kec is also available to be included in Standards Subscriptions.

The scope of this standard is the information model that extends the base CIM for the needs of distribution networks, as well as for integration with enterprise-wide information systems typically used within electrical utilities.

IEC | IEC Webstore

SCADA is modeled to the extent necessary to support power system simulation and inter-control centre communication. Implementation profiles IEC This edition includes the following significant technical changes with respect to the previous one: Interface architecture and general recommendations IEC This edition includes the following significant technical changes with respect to the previous edition: Allows the exchange of instance data in bulk.

eic Interfaces for records and asset management “Specifies the information content of a set of message types that can be used to support many of the business functions related to records and asset management. This new edition includes the following significant technical changes with respect to the previous edition: Major changes with respect to the ice edition are summarized below: Provides a glossary for the volume of work produced as part of the IEC series of publications.

Subsequent clauses of this standard are based on each interface identified in the IRM. This second edition contains numerous new terms in support of IECas well as revisions to terms found in the first edition. Guidelines for management of schematic definitions through multiple revisions are also included. This standard is intended for two distinct audiences, data producers and data recipients, and may be read from two perspectives.

  ENTEROBACTER GERGOVIAE PDF

The CIM facilitates integration by defining a common language i. At the same time, this International Standard can be leveraged beyond information exchanges defined by IECsuch as for the integration of market systems or general enterprise integration. From the standpoint of model export software used by a data producer, the document describes a minimum subset of CIM classes, attributes, and associations which must be present in an XML formatted data file for model exchange.

Finally, it makes it possible for utilities to locate customer telephone complaints and supervise the location ice field crews.

Typical uses of the message payloads defined in IEC include data acquisition by external systems, fault isolation, fault restoration, trouble management, maintenance of plant, and the commissioning of plant.

IEC – Wikipedia

Interface for network operations IEC Included in this part of IEC are the general use cases for exchange of diagram layout data, and guidelines for linking the layout definitions with CIM data. Thus, the imported network model data should be sufficient to allow performing network connectivity analysis, including network tracing, outage analysis, load flow calculations, etc.

Diagram layout profile IEC Methods and technologies used to implement functionality conforming to these interfaces are recommended in IEC

Author: admin